780-715
Nonlockout Models. Flame rectification system. Use with gas valves 7000 BDER, 7100 DER and 7200IPER. Replaces SP715 and SP715A.
Robertshaw ignition control units used in the Uni-Line 712 Series kits are C.S.A. design certified to applicable A.N.S.I. standards.
| Spark rate | 3 to 4 sparks per second |
| Pilot valve | 1 amp at .5 PF |
| Main valve | 1 amp at .5 PF |
| Combined load | 1.5 at .4 PF |
| Flame sense current | .7 mA DC @ 25°C / 24 VAC |
| Maximum total current load | 1.5 amp |
| Flame failure reignition time | .8 seconds maximum |
| Thermostat anticipator setting | .7 amp |
| Ambient rating | -40°F to 175°F (-40°C to 80°C) |
| Relative humidity | 95% noncondensing at 104°F |