Honeywell VR4300A4502 120V STANDING PILOT NATURAL GAS VALVE 3/4" X 3/4"
Product Description
Overview
Combination gas control for use in 120 Vac, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features
- Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Compact size.
- Provides two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meets codes requiring dual safety shut-off.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- LITE-RITE (OFF-PILOT-ON) lighting sequence.
Product Specifications
- Application
- Single Stage
- Includes
- 393691 Natural to LP gas conversion kit.; Two 3/4 x 1/2 in. reducer bushings; One 1/2" x 3/8" reducer bushing
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Frequency
- 60 Hz
- Tradeline Value
- Tradeline
- Electrical Connections
- 1/4 in. male quick connects; 24 in. (610 mm) leadwire.
- Voltage
- 120 Vac
- Operating Temperature Range (F)
- 0 F to 175 F
- Operating Temperature Range (C)
- -18 C to +79 C
- Body Pattern
- Straight-through with flange
- Opening Characteristics
- Standard Opening
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 3/4 in. x 3/4 in.
- Pilot Gas Outlet
- Compression fitting for 1/4 in. OD tubing
- Pressure Tapping
- 1/8 in. NPT with plug
- Approvals, American Gas Association
- AGA Design Certified: File No. L2025006; CGA Design Certified: File No. L2025006
- Type of Fuel
- Natural
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 200,000 BTUh: 30,000 BTUh minimum: 300,000 BTUh maximum Natural Gas
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. wc
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Standing Pilot
- Anticipator Setting
- 0.13 A